All evidence

Fouling Forecast

Can existing measurements give useful warning before an exchanger’s duty becomes unacceptable? We compared seven forecasting methods on complete campaigns the models had never seen.

Simulated data. No real plant results. Open the interactive report

What we found

On 24 test campaigns shifted away from training conditions, Causal trend (a simple local trend baseline) achieved the lowest threshold-crossing timing error at 1.38 days MAE, compared with 2.25 days for Grey hybrid.

White hybrid had the lowest outlet temperature RMSE (1.53 K vs. 1.70 K for Causal trend). No single method won across every metric, so a blanket claim for hybrid modelling isn’t supported.

Grey hybrid achieved 100% simultaneous coverage on shifted cases, but its temperature interval averaged 44.65 K—too wide to plan a cleaning around.

Simulated data

Threshold-crossing timing error on shifted campaigns

Mean absolute timing error (MAE, days) across 24 shifted synthetic test campaigns. Lower is better. Expand the table for outlet temperature RMSE (K) and interval width.

  1. Causal trend 1.38 Causal trend Timing MAE 1.38 days Outlet temp. RMSE 1.70 K Mean band width 8.86 K
  2. Grey hybrid 2.25 Grey hybrid Timing MAE 2.25 days Outlet temp. RMSE 1.72 K Mean band width 44.65 K
  3. White hybrid 3.17 White hybrid Timing MAE 3.17 days Outlet temp. RMSE 1.53 K Mean band width 8.26 K
  4. Black hybrid 3.23 Black hybrid Timing MAE 3.23 days Outlet temp. RMSE 2.05 K Mean band width 7.99 K
  5. Fixed rate 5.85 Fixed rate Timing MAE 5.85 days Outlet temp. RMSE 2.59 K Mean band width 10.72 K
  6. Direct ML 15.15 Direct ML Timing MAE 15.15 days Outlet temp. RMSE 5.87 K Mean band width 9.78 K
View full metrics table
Method Timing MAE (days) Outlet temp. RMSE (K) Mean band width (K) Simultaneous coverage
Causal trend 1.38 1.70 8.86 96%
Grey hybrid 2.25 1.72 44.65 100%
White hybrid 3.17 1.53 8.26 98%
Black hybrid 3.23 2.05 7.99 78%
Fixed rate 5.85 2.59 10.72 80%
Direct ML 15.15 5.87 9.78 19%

5 model seeds on one synthetic fleet. Persistence is left out because it never predicted a crossing, so it has no timing error.

How it was tested

A two-stream countercurrent thermal model generated 88 synthetic campaigns with disturbances, sensor noise and cleaning residuals. Forecasts used only data available on the forecast day.

Whole campaigns were held out: 24 training candidates, 20 for calibration, 20 nominal tests and 24 shifted tests. Five seeds varied the models on one fixed fleet, so they are not independent plants.

What it doesn’t show

This is a lumped single-phase model. It doesn’t represent a full refinery train, and it doesn’t establish savings, reliability or readiness for use on a plant.

It does show the method we’d apply to your historian data: simple baselines first, unseen test campaigns, and failures in plain view.

Run this test on your exchangers.

See the pilot