All evidence

Wastewater Watch

A cross-domain methodology stress-test on a published synthetic benchmark (IWA BSM1). It demonstrates how we evaluate dynamic forecasting models under operating shifts, rather than oil and gas field work.

Simulated data. No real plant results. Open the interactive report

What we found

Black hybrid beat Persistence on six-hour rain forecasts (1.06 vs. 1.41 mg N/L NH4 RMSE). On six-hour storm cases the two were nearly tied (1.51 vs. 1.52 mg N/L).

Grey hybrid struggled under changed conditions and over longer horizons. Simply assuming nothing changes (Persistence) remained hard to beat.

Simulated data
Six-hour NH4 forecast error (RMSE, mg N/L). Lower is better. 4 test scenarios per weather regime.
MethodRainStorm
Black hybrid1.061.51
Persistence1.411.52
Direct ML1.512.51
Local trend1.891.97
White hybrid2.944.30
Grey hybrid3.084.58
Fixed physics3.334.52

How it was tested

Seven methods ran on 28 custom scenarios of the open-loop IWA Benchmark Simulation Model No. 1 (BSM1; Alex et al., 2008; Jeppsson et al., 2007) implemented via BSM2-Python (BSD-3-Clause), with six-hour and 24-hour rolling forecasts using no future control data.

What it doesn’t show

Four test scenarios per regime can’t support broad conclusions. The scenarios come from one simulator set-up, and the 4 mg N/L alert level is illustrative, not a regulatory limit.

It claims no real-plant savings, compliance performance or automatic treatment control.

Could your data give useful warning?

Start with an audit